Coating Thickness Gage (Basic Type) (Model No. HVO-ISO-1200FN)
Coating Thickness Gage
Specification:
- Measuring Range: 0-2000μm
- Resolution:
1μm (100μm range<1000μm);
0.01mm (1.00mmsranges 2mm)
- Accuracy: ±(2µm+3%L) ('L' is measuring thickness in µm)
- Measuring Interval: 0.5s
- Calibration Mode: zero calibration
- Measuring Mode: Fe, NFe, Fe/NFe
- Minimum Substrate thickness: Fe (0.2mm), NFe (0.05mm)
- Minimum measuring area: Ø25m
- Minimum curvature radium of workpiece:
Concave Surface: 25mm
- Unit: µm/mil
- Power supply: 2x1.5V AA batteries
- Main Unit Dimension: 101x62x28mm
- Probe Dimension: 71x26x22mm
- Weight: 114g
Features:
- Probe is suitable for both magnetic and non-magnetic metal substrates
- Can measure the thickness of non-magnetic coating and non-metallic
coating on magnetic metal substrate
Substrate: iron, steel, magnetic stainless steel (not for non-magnetic stainless steel) Coating: zinc, aluminum, copper, chrome, tin, plastic, powder, paint (not for nickel) - Can measure the thickness of non-conductive coating on non-magnetic metal substrate (Substrate: copper, aluminum, zinc, non-magnetic stainless steel
Coating: plastic, powder, paint, anodizing (not for chrome and zinc plating)
- 3 measuring modes: Fe, NFe, Fe/NFe
- Store 9 measuring records
- Small and portable, easy for operation
Standard Delivery
- Main Unit: 1Pc
- Fe zero calibration plate: 1Pc
- NFe zero calibration plate: 1Pc
- Standard foil (100µm): 1Pc
- 1. 5 V AA battery: 2Pc