High-Performance Liquid Chromatography With Rheodyne Injector (Model No. HV-6300)

High-Performance Liquid Chromatography With Rheodyne Injector (Model No. HV-6300)

HOVERLABS

  • Rs. 1,298,500.00
8

Features :

  • Improve the maximum limited pressure by precise tranducer
  • Accord with GMP/GLP, ISO9001, 21 CFR Part II with CDS (Software)
  • Online Washing Device while analysis
  • Self - priming pump head requires no manual priming
  • Available with micro, analytical, semi-prep, and prep pump heads
  • Programmable solvent compressibility compensation
  • Easy maintenance and service for all wetted parts

Specifications :

  • Flow Range    :    0.001-9 .999 ml/min
  • Delivery method    :    Double piston (Main & Auxiliary)
  • Pump head    :    10ml SST/Peek analytical
  • Accuracy    :    ± 1% or ± 2μL/min, whichever is greater / ± 1% or ± 1μL/min, whichever is greater (Micro)
  • Flow rate settings    :    0 - 0.10 mL/min. 0.001 in c. , 0.10-0 .90 mL/min. 0.010 inc., 1.0 mL/min.+ 0.10 inc .
  • Precision    :    0.1% RSD
  • Pmax    :    9999 psi
  • System connection s    :    1/16’’ capillaries
  • Dimensions    :    130 mm x 260 mm x 420 mm
  • Weight.    :    11 kg
  • Power input    :    85 to 264 VAC, 47 to 63 Hz, 60 Watts
  • Display    :    300mm


UV-VIS Spectrophotometer Detector

Features :

  • Unique pool structure ensures the accuracy and sensitivity of the instrument
  • Easy maintenance a nd service for all wetted parts
  • High-quality structure
  • Long life deuterium lamp
  • Easily replace
  • Advanced design

Specification :

  • Wavelength    :    190-700 nm
  • Spectral bandwidth    :    6 nm
  • Wavelength Accuracy    :    ≤±1 nm
  • Wavelength Reproducibility    :    ≤± 0.1 nm
  • Flow pool volume    :    8μ L
  • Optical path    :    10 mm
  • Dynamic Noise    :    ≤± 0.75×10 5AU (Methanol, 1ml/min, 254nm, 20°C)"
  • Static Noise    :    ≤± 0.5×10 5AU(Empty pool, Response time 1 s, 20 °C)"
  • Dynamic Drifting    :    ≤±1×10 - 4AU (Methanol, 1ml/min, 254nm, 20°C )
  • Static Drifting    :    20 °C) ≤± 0.5×10 - 4AU(Empty pool, Response time 1 s,"
  • Qualitative repeatability    :    RSD ≤ 0.1%
  • Quantitative repeatability    :    RSD ≤ 0.5%
  • Dimensions : 130H x 260W x 420 D, (mm )
  • Weight.11 kg

Standard Configuration :

  • Liquid Constant flow Pump  :  2 set
  • UV-VIS Spectrophotometric Detector   :  1 set
  • System Controller    :   1 set
  • Mixer    :  1 set
  • Injector    :   1 set
  • Chromatography data sys tem :  1 set
  • Chromatography column    : 1 set